Click for more products.
No produts were found.
-
Products
-
HVAC & heat pump
-
Electricity
-
Hydraulic
-
Heating spare parts
-
Air heater
-
Burner
-
Manufacturer
-
Fuel oil
-
Gas
-
Cable and lug
-
Carbon monoxide and gas detection system
-
Gas hose and accessories
-
Motor and capacitor
-
Piezometer
-
Thermocouple
-
Gas block and accessory
-
Gas line
-
Pilot burner and injector
-
Cell and test unit
-
Electrode and probe
-
Burner flange gasket
-
Air flap actuator and servomotor
-
Transformer
-
Valve
-
Baffle
-
Air flap
-
-
Wood pellets
-
Oven and roaster part
-
Maintenance and servicing
-
Autres pièces pour cheminée, insert et poêle
-
Capteur, écran, télécommande
-
Circuit imprimé
-
Pièce électrique, câble et gaine
-
Extracteur et accessoires
-
Motoréducteur
-
Sonde, thermocouple
-
Tresse insert, cheminée, poêle
-
Bougies
-
Grille en fonte et creuset
-
Pressostat, Thermostat, klixon
-
Ventilateur
-
-
-
Sanitary
-
At the moment
-
Maintenance & Servicing
-
Water heater parts
-
Control & Measurements
-
Radiator valves
-
Ventilation & Heat insulation
-
Stock clearance
-
-
Brands
-
Exploded Views
-
Stock clearance
Click for more products.
No produts were found.
Motorpump low pressure cam 80 1-phased 1900l/h- DIFF - 309491
Group for domestic fuel. USED : It is used for boilers installations far from the fuel tank. It must be installed near the fuel tank and plugged with the burner strater. The installation is one-pipe that is without return to the tank (the return occurs on the loop of the circuit). In order to determine the necessary flow to supply the installation it needs know the type of supply of the burner pump in place. If this pump is one-pipe ( no pipe connected to the return orifice or filter of recycling) it needs consider the nozzle flow in place and provide a margin of 50% higher.
€386.93
(tax excl.)
Reference:
Download PDF
309491
Add to wishlist
Group for domestic fuelUSED :It is used for boilers installations far from the fuel tank. It must be installed near the fuel tank and plugged with the burner strater. The installation is one-pipe that is without return to the tank (the return occurs on the loop of the circuit)In order to determine the necessary flow tosupply the installation it needs know the typeof supply of the burner pump in place.If this pump is one-pipe( no pipe connected to the return orifice orfilter of recycling) it needs consider the nozzle flow in place and provide a margin of 50% higher. For a burner pump connected intwo-pipe (filter with return pipe to the tank) it needs consider the flow of the burner pump and provide a margin of 50%higher.TECHNICAL FEATURES :Inlet max height 4 mInlet max length 8 mDiameter suction and pressure pipe 25mmFlow 380L/h for total height 36 metres(suction and return combined)Flow 1900L/h for total height 15 metres(suction and return combined)Voltage : single phase 220 VoltsPower 375W to 2800 turn/minuteSuction and return 3/4"NOTE: the fuel emulsifies if the height of the suction exceeds 4m and if the length ofpipe is too important that can break the group by suction of airSo the better working isworking under pressure on the circuit andinstalling the motorpump as close as possible of the tank (example: on the cover)
Read more
| Puissance (détails) | 220 mono | |
| Ø | 3/4'x3/4' | |
| Caractéristiques | Débit : 1900-380 | |
| Application | 8 et 9 | |
| Type | CAM 80 | |
| Raccord | 3/4'x3/4' |